100字范文,内容丰富有趣,生活中的好帮手!
100字范文 > 自然通风逆流湿式冷却塔 NDWCT英语短句 例句大全

自然通风逆流湿式冷却塔 NDWCT英语短句 例句大全

时间:2023-11-18 19:40:12

相关推荐

自然通风逆流湿式冷却塔 NDWCT英语短句 例句大全

自然通风逆流湿式冷却塔,NDWCT

1)NDWCT自然通风逆流湿式冷却塔

1.As an effective cooling equipment, natural draft wet cooling tower (NDWCT) is used widely to cool circulating water for power plant thermodynamic system, and has a direct and important impact on the safety, economy and effectiveness of power plant cold end system.自然通风逆流湿式冷却塔作为有效的冷却设备,广泛用于电站热力系统循环水的冷却,其冷却性能直接影响电站冷端系统的安全经济高效运行。

英文短句/例句

1.Research on Evaporation Loss of Natural Draft Counter-flow Wet Cooling Towers;自然通风逆流湿式冷却塔蒸发水损失研究

2.Research on Flow Resistance of Inlet Air and Performance Optimization of Natural Draft Counterflow Wet Cooling Tower with Air Deflectors具有导风板的自然通风逆流湿式冷却塔进风阻力研究及性能优化

3.Performance Evaluation and Model Test on Influence of Wind of Natural Draft Counter-Flow Wet Cooling Towers;自然通风逆流湿式冷却塔性能评价及环境侧风影响的试验研究

4.Research on Water Distribution System of Natural Draft Counter-flow Wet Cooling Towers under Cross-wind Conditions;侧风环境下自然通风逆流湿式冷却塔的配水系统研究

5.Mechanism Research of Crosswind Effect on Heat and Mass Transfer in Natural Draft Counterflow Wet Cooling Tower侧风对于自然通风逆流湿式冷却塔传热传质影响机制的研究

6.Research on Optimizing Aerodynamic Field in Natural Draft Counter-flow Wet Cooling Tower;自然通风逆流湿式冷却塔空气动力场的优化研究

7.Diffuseness and Reduction of Wet-style Natural-ventilation Cooling Tower Noise;自然通风逆流湿式冷却塔噪音的传播规律及降噪研究

8.ONE-DIMENSIONAL CALCULATION METHOD OF THERMAL PERFORMANCE FOR NATURAL DRAFT COUNTER FLOW COOLING TOWER WITH WATER DISTRIBUTION IN THE OUTER AREA自然通风逆流式冷却塔外区配水一维热力计算方法

9.Numerical Simulation and Structural Optimization of Natural Draft Wet Cooling Tower自然通风湿式冷却塔数值模拟与结构优化

10.Numerical simulation for thermal performance of natural draft wet cooling tower自然通风湿式冷却塔热力特性数值模拟

11.Circumferential inflow air distributing rules in a natural draft wet-cooling tower under crosswind conditions侧风环境下自然通风湿式冷却塔周向进风变化规律

12.Discussion about Transverse-flow Natural Draft Cooling Tower北京某热电厂横流式自然通风冷却塔剖析

13.Code for design of counter flow-type mechanical draught cooling tower structure for petrochemical enterprises石油化工逆流式机械通风冷却塔结构设计规范

14.Study on Process and Performance of Reverse Flow Mechanical Ventilation Cooling Tower逆流机力通风冷却塔工艺性能的研究

15.A Numerical Simulation of the Heat Transfer in the Filler-free Cooling Tower with an Up-stream Mechanical Ventilation机械通风逆流式无填料冷却塔内热交换过程的数值模拟

16.Calculation Model and Influence Factors of Cooling Performance of Natural Draft Cooling Tower;自然通风冷却塔冷却性能计算模型及影响因素

17.induced draft mechanical cooling tower抽风式机械通风冷却塔

18.forced draft mechanical cooling tower鼓风式机械通风冷却塔

相关短句/例句

natural ventilation reverse flow cooling tower自然通风逆流式冷却塔

3)natural draft counterflow cooling tower逆流式自然通风冷却塔

1.There are many problems in thenatural draft counterflow cooling tower thermal performance tests and the routine tests.在火电厂逆流式自然通风冷却塔的热力性能验收试验以及大修前、后的常规热力试验中,由于测试工况数目较多,原始数据处理的工作量大,稍有不慎,就会出现错误;同时为了分析结果,往往将模拟塔或其它电厂的相同型号的冷却塔与当前的试验塔进行对比评价。

4)wet-style natural-ventilation cooling tower湿式自然通风冷却塔

1.The water-spouting noise is the dominant noise source of thewet-style natural-ventilation cooling tower.淋水噪声是湿式自然通风冷却塔的主要噪声源,噪声频谱表现为中高频特性。

5)counter-flow wet cooling tower逆流湿式冷却塔

1.Water-saving ofcounter-flow wet cooling tower is the key of water-saving work for the thermal power plant.逆流湿式冷却塔的节水是火力发电厂节水工作的关键。

6)natural draft dry cooling tower自然通风干式冷却塔

1.The influence of cross wind on the air flow field in anatural draft dry cooling tower is studied experimentally on the basis of similarity rules.本文通过模型实验手段研究了横向风对自然通风干式冷却塔空气流场的影响问题。

延伸阅读

自然通风自然通风Nnatural ventilation2 Iran tongfeng自然通风(natural ventilation)在风力造成的风压和厂房内外空气温差引起的热压的作用下,使空气流动的工厂全面通风方法之一。通过改变开启窗孔的位置及其面积来调节进人、排出气量的自然通风,称为有组织的自然通风,统称自然通风。通过围护结构缝隙进出的自然通风换气量是难以调节的,这种通风方式称为无组织自然通风或称渗透通风。工厂自然通风都是指有组织的自然通风。它是不消耗动力,而可以获得巨大通风换气量的一种经济节能的通风方式。尤其是热车间中被广泛用于全面通风,也可用于实现某些热设备的局部通风。自然通风窗孔的进、排风量计算式为:。一:寸粤亘式中G为进风、排风量,kg/s;F为窗孔的面积,mZ;尸为空气密度,kg/m3;宁为窗孔的局部阻力系数;△p为窗孔内外两侧的压差,Pa。当F、泞、p一定时,G随着△P的增大而增加。么P的大小则是由风压Pf与热压p决定,△p一p,+pr。风压风流经建筑物时,在周围形成的静压与稳定气流静压的差值。风吹过建筑物周围形成绕流运动(图1),其四周气流的压力发生变化。迎风面气流受阻,动压降低,静压升高;侧面、背风面产生涡流,静压降低。迎风面为正压区,处在该区的窗孔为进风,侧面与背风面为负压区,该区窗孔为排风。风压值pf可按下式计算: 。P,二乙 P;~Ki二资竺2式中p、为室外温度t、下的空气密度,kg·m一“;二,为室外风速,m·51;K为空气动力系数,与建筑物形状、尺寸和风向有关,通过实验求得。K值为正者风压为正,反之风压为负。室外风速、风向经常变化,一、_谭「酒一_…蒙幸… —-一一自然通风计算包括两类问题。(1)设计计算。按照工艺条件和工作区温度要求计算出的所需全面通风妇建粉万荀脚汀又挽粼快幼换气量,设计和计算出车间进排风窗孔位置及其面积·(2)校核计算。根据建筑物上已有的窗孔位置和面积,天之中也不稳定。、,,.,,、二。。*。~、一华。~‘。~~口二、八~‘匕‘”‘沁~。计算出通风换气量,校核工作区温度是否满足要求。 热压由于室内外温度差引起的室内外压力差。为满足工作区温度要求所需要的全面通风换气量在厂房外墙上开有上下两排窗孔a、b。厂房中产生的。二、:一,小、仙‘脚‘’明一”一门一’r”排曰‘“‘、一”’,/J”一~G的计算式为:热压△p,为:n二、、一一。r/‘·。Q、‘一L,。